Skip to main content

Uniphore Customer Portal

Specification and Requirements

This topic provides general information related to prerequisites, as well as system capabilities and considerations.

Prerequisites
Prerequisites – Customer Specific
Prerequisites – Uniphore Specific (U‑Capture)

In general, there are no additional U‑Capture system requirements specific to a Cisco Active integration.

Call Recording Capabilities
Call Metadata
Integration Dependent Features
U-CaptureCisco

Recording

Supported Media

Voice

Max Supported Channels (per Collector)

3000

Mono/Stereo Recording

Stereo

Record Internal Calls

Y

Record Encrypted Calls

Y

Supported Codecs

See Codec Support

Single Call Through Hold

N

Device Discovery

Automatic

Device Enablement *

Auto Enable (Configurable)

Silence Suppression *

Y

Discard Call on Silence *

N

Recording Alarms

Y

U‑Capture Collector

Recommended Resiliency Model

Top-Down Failover

Additional Supported Resiliency Model

NA

U‑Capture

Linked Calls

Y

Blocklist

Y

Other Features

Requires CTI Feed

N

* Just to clarify a few features:

Single Call Through Hold: When a call is put on hold the recording appears as a single recording or is split into multiple calls.

Device Enablement: Indicates if new devices are automatically enabled or disabled for recording. Configurable – default is automatically enabled.

Silence Suppression: Recording of silence is suppressed. Only supported for the G.711 Codec. Not supported for SRTP.

Note

Features highlighted Y above are supported by U‑Capture. Certain features may not be supported by the telephony platform. For example, a trunk gateway is unlikely to send internal calls to the Collector.

Codec Support

A wide range of codecs are supported. The table below shows the currently supported codecs and some key attributes

Codec

Algorithm

Bitrate (Kbps)

Sampling Frequency (Hz)

Audio Bandwidth

MOS

G.711

PCM

64

8000

300 Hz – 3400 Hz

4.10

G.722

SB-ADPCM

48, 56, 64

16000

50 Hz – 7 kHz

4.10

G.722.1

MLT

24, 32

16000

50 Hz – 7 kHz

4.00

G.723.1

ACELP

MP-MLQ

5.3

6.3

8000

8000

3.62

3.90

G.726

ADPCM

16

24

32

40

8000

8000

8000

8000

200 Hz – 3400 Hz

3.50

4.10

G.728

LD-CELP

16

8000

3.61

G.729

CS-ACELP

8

8000

140 Hz – 3600 Hz

3.92

G.729A

CS-ACELP

8

8000

140 Hz – 3600 Hz

3.70

AMR

ACELP

Variable (4.75 – 12.2)

8000

3.50 – 4.10

AMR-WB

ACELP

Variable (6.6 – 23.85)

16000

IMA ADPCM

ADPCM

32

44.1

64

88.2

8000

11025

16000

22050

GSM 06.10

RPE-LTP

13

8000

3.60

Opus

LPC

Variable (6 – 510)

8000

12000

16000

24000

48000

4 kHz

6 kHz

8 kHz

12 kHz

20 kHz

Networking Considerations
Firewall Port Considerations
Security
Secure SIPSecure RTPSession Parameters
Voice Activity Detection
Tested Configuration