Specification and Requirements
This topic provides general information related to prerequisites, as well as system capabilities and considerations.
Prerequisites
Prerequisites – Customer Specific
Prerequisites – Uniphore Specific (U‑Capture)
In general, there are no additional U‑Capture system requirements specific to a Cisco Active integration.
Call Recording Capabilities
Call Metadata
Integration Dependent Features
Recording | |
Supported Media | Voice |
Max Supported Channels (per Collector) | 3000 |
Mono/Stereo Recording | Stereo |
Record Internal Calls | Y |
Record Encrypted Calls | Y |
Supported Codecs | See Codec Support |
Single Call Through Hold | N |
Device Discovery | Automatic |
Device Enablement * | Auto Enable (Configurable) |
Silence Suppression * | Y |
Discard Call on Silence * | N |
Recording Alarms | Y |
U‑Capture Collector | |
Recommended Resiliency Model | Top-Down Failover |
Additional Supported Resiliency Model | NA |
U‑Capture | |
Linked Calls | Y |
Blocklist | Y |
Other Features | |
Requires CTI Feed | N |
* Just to clarify a few features:
Single Call Through Hold: When a call is put on hold the recording appears as a single recording or is split into multiple calls.
Device Enablement: Indicates if new devices are automatically enabled or disabled for recording. Configurable – default is automatically enabled.
Silence Suppression: Recording of silence is suppressed. Only supported for the G.711 Codec. Not supported for SRTP.
Note
Features highlighted Y above are supported by U‑Capture. Certain features may not be supported by the telephony platform. For example, a trunk gateway is unlikely to send internal calls to the Collector.
Codec Support
A wide range of codecs are supported. The table below shows the currently supported codecs and some key attributes
Codec | Algorithm | Bitrate (Kbps) | Sampling Frequency (Hz) | Audio Bandwidth | MOS |
---|---|---|---|---|---|
G.711 | PCM | 64 | 8000 | 300 Hz – 3400 Hz | 4.10 |
G.722 | SB-ADPCM | 48, 56, 64 | 16000 | 50 Hz – 7 kHz | 4.10 |
G.722.1 | MLT | 24, 32 | 16000 | 50 Hz – 7 kHz | 4.00 |
G.723.1 | ACELP MP-MLQ | 5.3 6.3 | 8000 8000 | 3.62 3.90 | |
G.726 | ADPCM | 16 24 32 40 | 8000 8000 8000 8000 | 200 Hz – 3400 Hz | 3.50 4.10 |
G.728 | LD-CELP | 16 | 8000 | 3.61 | |
G.729 | CS-ACELP | 8 | 8000 | 140 Hz – 3600 Hz | 3.92 |
G.729A | CS-ACELP | 8 | 8000 | 140 Hz – 3600 Hz | 3.70 |
AMR | ACELP | Variable (4.75 – 12.2) | 8000 | 3.50 – 4.10 | |
AMR-WB | ACELP | Variable (6.6 – 23.85) | 16000 | ||
IMA ADPCM | ADPCM | 32 44.1 64 88.2 | 8000 11025 16000 22050 | ||
GSM 06.10 | RPE-LTP | 13 | 8000 | 3.60 | |
Opus | LPC | Variable (6 – 510) | 8000 12000 16000 24000 48000 | 4 kHz 6 kHz 8 kHz 12 kHz 20 kHz |